Simulation workbench

Open without AI

Open Simulations → Simulation workbench…, or Studies → Dynamic simulation…. If a detached study copy is needed, the app offers Prepare study from current network; preparation is explicit and sends no AI message. Original is not replaced. A saved RMS case or RMS result link opens the same bound workbench. Other study methods remain in Study Manager; EMT retains its existing viewer.

Prepare and run exact inputs

Select a named case and exact version, or a retained run. Use the single Study panel selector: Setup, Events, Models, Channels or Run details. Setup contains profile, step and end time; Models retains declared templates and provenance. The full selected case/run name and original UTC timestamp appear beneath the toolbar. Existing setups are read-only. Study actions → New case version…, adjust the admitted timing, then Study actions → Save setup retains a new immutable version against the same source. Missing models/provenance or inactive/unsupported events are not repaired automatically. An unsaved draft asks for Save/Discard/Cancel before navigation. Save continues the selected navigation automatically only after a successful immutable save. A failed save keeps the draft and does not navigate.

Run study submits the selected exact version to the persisted isolated worker. For a replayable retained run it first creates a named frozen case from that receipt, never from the current editor. The toolbar shows the actual job state and elapsed time, separately from engineering disposition. Failed, interrupted, cancelled, partial or unavailable results are never labelled successful because a receipt exists. Selecting an exact case with an active persisted job reconnects to that job only; opening a retained run never switches to an unrelated job. Named runs use their original submission name and UTC timestamp, not the current case head; older unnamed recordings retain an explicit timestamp fallback. Cancel requests cancellation of that job only; wait for its terminal state. Opening, plotting, playback and export never run a solver. Previous result evidence is retained, including failed/cancelled runs. A failed input/asset check remains explicit in the corresponding panel and Source details.

The RMS /2 step is 5 or 2.5 ms, with duration 0.5–100 s in 0.5 s increments and at most 20,001 samples (50 s maximum at 2.5 ms). Retained RMS /1 remains 5 s / 5 ms. All declared groups must be active and are simulated; comparison checkboxes do not change these inputs. See Balanced RMS dynamics for the remaining admission and numerical limits.

Compare, locate and play

Open Study panel → Channels, search the equipment/quantity tree, select a quantity with its recorded unit, then choose Upper plot or Lower plot. Group checkboxes change comparison visibility only. External colour-keyed rows show each exact group name and cursor value without covering the traces. Each plot retains its native declared unit, with common group colours and a shared exact-sample cursor. Unresolved units are not assigned an invented physical unit. Toggle Pan independently on either plot, use the mouse wheel to zoom, and Fit to restore the recorded time extent and that plot’s y extent. Both plots share the time viewport; each keeps an independent y range. Changing channels or group visibility preserves the time zoom and leaves the other quantity’s y range unchanged. A plot click seeks the nearest retained timestamp.

The grid and read-only native source use the chosen event group and integer sample index. Select a bus row or schematic object to link the selection; a bus with a Vm channel selects that upper plot. Grid values show Vm in pu and Va in rad alongside source nominal kV and source voltage limits. Those limits are not transient acceptance criteria. Source labels and model values are not overwritten by playback. Generated drawings are labelled as generated and are not saved back.

Play/Pause, speed, the time slider, declared-event timeline and event selector move through actual samples, never interpolation or a live solver. Home/End and arrow keys on the slider/timeline seek first/last/adjacent samples. Playback pauses when hidden/inactive. Event rows name the declared native change and its target. Simultaneous changes are grouped on the timeline, while nearby timestamps retain separate markers and staggered labels. Conductance/susceptance changes are not automatically called physical faults. Event-table tooltips retain raw fields, requested time, native schedule and measured transition details where recorded; an event marker alone is not proof of physical onset. Unknown/failed/missing data remains unavailable, not zero.

Export, evidence and layout

Study actions → Export recorded CSV… asks for a destination and atomically exports the two selected resolved channels, visible groups and full retained recording, with channel IDs, units, receipt and artifact hashes. Export runs off the GUI thread. Study actions → Source and run details… exposes exact configuration, solver/model identities, limits and warnings. No plot, run, export or case version grants engineering approval or applies changes to Original.

Wide windows show a compact Study panel, source, two plots and the bus grid together. Below 1440 logical pixels, Plots retains both graphs together, alongside Network / Values tabs and the single Study panel section selector. Below 1000 logical pixels the sidebar starts hidden; Study panel on the toolbar reveals it without squeezing both plots. Docks resize/rearrange; Study actions → Restore this layout recovers the default composition. Compact and wide layouts are saved separately; crossing a width breakpoint does not discard a customized dock arrangement. Tables scroll intentionally when the viewport cannot fit all exact columns; full identities remain in tooltips/details. Layout preferences are separate from receipts and engineering state. Existing unsaved projects and other applications are not closed by this workflow.

The lower timeline and seek selector contain events only for the chosen disturbance case; a baseline without events remains empty. Dotted plot markers refer to the visible comparison cases, not every hidden case. Native loader diagnostics remain in Source and run details…, even when final source pointers resolve. The bundled v6 synthetic example gives each event its own identity; legacy archives and retained results are not rewritten.

Open in Map opens the recorded study map with the same verified recording, case, sample and selected equipment. Return with Open in Simulation; neither action applies to Original or requires AI.