Geographic Map: source, recorded results and navigation
Prerequisites and entry
Open a native project, then choose Map in the rail or Geographic map in Native view. No AI conversation is required. Working network reads the current engineering declarations; Recorded study reads one exact retained RMS receipt and its source artifact. The saved-study list is project-wide and paginated. Changing a chat conversation/candidate does not invalidate a project Map; changing project or account does.
If equipment has no source coordinates, the Assets tab and source/result tables remain usable. No map, solver result, position or engineering approval is invented. View → Edit working coordinates… explicitly opens the separate working-coordinate editor/import. Recorded sources cannot be edited here. Import requires exact native IDs, explicit supported coordinate declarations and human review; it never repairs unknown coordinates silently.
Project → Create populated harbour study example… opens a separate synthetic Rotterdam-area project, isolated preferences and a real retained RMS study. First preparation runs the isolated solver worker. Reopening the retained example does not rerun it or replace an existing project. Positions are illustrative assumptions, not real utility assets or surveyed cable routes.
Navigate and inspect
The top row chooses source/study/case; the second row keeps previous/next extent, zoom, Fit network, Locate, quantity, background and View reachable at narrow widths. Full names remain in selector tooltips/dropdowns; a clipped study gets an additional full identity line.
Select equipment in the map, Assets tree, results table or linked source schematic. All use the same stable source ID; selection alone does not pan. Locate fits the actual available station/bus or branch/transformer geometry. Fit network frames supplied stations/routes, with room for labels. A fitted view remains fitted when resized; after manual navigation, resizing preserves its camera instead. In the focused map use arrows to pan, +/− to zoom, Home to fit, and Alt+Left/Right for extent history. Labels prioritize selected equipment and hide crowded lower-priority annotations rather than draw long crossing leaders. Inspect the selected object to see concealed detail.
Assets and Layers are separate tabs. Search matches exact native IDs as well as names, including a bus represented by a single-station row. Unplaced equipment remains explicit. Layer checkboxes independently control stations, routes, names and recorded labels. The overview shows network extent/current viewport and supports deliberate repositioning. Dashed transformer connections show electrical topology between supplied stations, not a surveyed geographic route.
View can reopen Layers/assets, Selected equipment, Recorded results and the linked source schematic without resetting the whole layout. Compact/wide dock layouts and source-scoped camera/layer/selection preferences are disposable UI state, not engineering authority.
Engineering values and interpretation
The inspector separates declared inputs from recorded case comparisons and relevant case events. Declared in-service state is not live telemetry. Coordinate provenance is labelled separately from exact-device electrical model provenance; missing provenance remains unrecorded, not a manufacturer attestation.
Buses shows native nominal kV, exact-sample Vm [pu], Va [rad] and declared source Vmin/Vmax [pu]. A multi-bus station requires an explicit bus choice. Branches / transformers defaults to derived terminal MW/MVAr, loading reference and recorded connection state, alongside declared continuous rating [MVA]. Engineering-unit columns show MW/MVAr using the exact source Sbase and maximum-terminal apparent loading against the declared continuous rating. Raw pu channels remain in the receipt/tools. Missing source bases or ratings stay unavailable; no independent acceptance is inferred. Missing channels/cases remain Unavailable, never zero. Displayed values use concise precision; tooltips/evidence and exports retain source identity.
Choose Voltage or Angle for station fill/labels. The numeric legend uses a recording-wide finite range across available cases/times, so its scale does not change every sample. Grey means unavailable or an unresolved multi-bus choice. Route colours remain source nominal-voltage classes. Neither result colour nor source voltage limits are transient acceptance criteria. Click an available case comparison row to select that exact recorded case; the branch comparison quantity selector compares one terminal quantity clearly without squeezing four numeric fields into the sidebar.
Playback, sample slider and case-specific event seeking use actual retained timestamps; they neither interpolate results nor rerun a solver. Map and Simulation share the same receipt/case/sample selection. Playback pauses when hidden/inactive. Zero, unavailable, execution completion and engineering approval stay distinct.
Background, privacy and recovery
Use the single Background selector for Off, Coordinate grid or Street map · OpenStreetMap. The grid is not a real basemap. Streets require explicit native consent: the provider receives your network address and visible area. Consent is remembered only for the bound project/account/provider and can be revoked through View. Without that scoped consent, the window stays offline. This changes neither AI tool permissions nor engineering authority. No public-tile bulk download or offline archive is provided.
Footer status distinguishes loading, cached streets, partial availability and provider failure, with attribution visible online. Failure preserves the electrical network and exact results; retries are bounded and opt-out retires workers asynchronously. Background switches preserve the floating-point camera/overlay alignment. Selecting a new study preserves the previous source until verification succeeds. Retry unavailable source only retries source reading; it does not run or repair engineering work.
Evidence, exports and exact startup
Export displayed table… asks for a destination and writes the currently chosen bus/branch table in its displayed sort order, with source IDs, exact numeric precision, receipt/source/case/sample/time identities and native units. Playback after clicking does not change that snapshot. Export bus time series (all samples)… writes Vm/Va channels for the chosen case over its whole retained recording, not only the displayed instant. Writes are atomic and off the GUI thread; existing-file overwrite requires the native file dialog confirmation. Review the exported file before using it as evidence.
Source and recording details… separates readable binding details, preserved native import diagnostics and the deeper technical record. A study is not engineering approval; neither export nor Map grants Review/Apply.
The project remembers the last retained recording and view. Explicit checkout launch: PYTHONPATH=src NUMBA_CPU_NAME=generic .cache/veragrid-runtime/bin/python -m powersystem.desktop PROJECT --state STATE_DIRECTORY --open-study RECEIPT --study-view map. RECEIPT is the full project-bound 64-character hash. Missing/incompatible data reports the problem, never substitutes a new run. Original/Main and existing owner windows remain untouched.
Exact engineering state and verification
G identifies a source and ▼ a demand attached to the station; the paired rings identify a transformer connection. Route colours indicate nominal voltage, while the station colour scale indicates the selected measured quantity. An orange outline is a separate source-limit warning, not a high/low colour-scale judgement. Labels show nominal kV and the recorded pu value. These illustrative connections are not surveyed routes.
Verified switch events are replayed up to the selected group's exact sample. An open branch is grey/dashed and marked OPEN; seeking before its event restores the source connection. Unknown event effects remain unavailable. The linked read-only schematic uses the same receipt, artifact, group and sample without changing Original. View → Show recorded power flow / loading adds compact from-terminal MW and continuous-rating reference percentages (hover for MVAr and exact identity); selected, open and overloaded connections also show a label. MW/MVAr are converted with the immutable source's MVA base, never an assumed base. Loading is max terminal MVA / declared continuous rating, not transient equipment qualification. The branch table defaults to engineering units and recorded connection state. Raw pu channels remain in the retained evidence and paged study tools.
The compact Checks button exposes separate Equations, source limits and initial AC reference verdicts in its tooltip and dialog. Checks opens a virtual findings table (failures/unavailable first; clear the filter to inspect all checks). Each finding retains equipment/group identity, worst sample time, residual or observed value, bounds and tolerance. Checks → Verify results queues an isolated audit of the exact owned retained receipt; it does not rerun a different current network or change model data. Read the completed audit before drawing a conclusion. Missing/corrupt data, unsupported devices or unavailable reference runtimes never become a pass.
For the admitted balanced AC profile, checks include branch terminal equations, nodal complex-power balance, losses and declared voltage/generator/rating limits. The admitted RMS profile checks all retained samples, verified event parameter changes, load/shunt/network/generator algebraic equations and backward-Euler state defects. Nodal/terminal tolerance is 0.0001 MVA and normalized dynamic-model tolerance is 0.000001; source constraints remain a separate verdict. The independent pinned pandapower comparison matches only the source AC initialization. It is not independent dynamic simulation, plant qualification or approval. Controlled taps, unsupported models and incomplete data are explicitly uncovered; inspect the checks rather than assuming universal coverage.
AI in Build may submit study_submit(kind="verification", target_receipt="<exact owned SHA256>"), then poll study_status and read paged study_results/study_evidence. Plan reads existing evidence only. There is no AI capability to approve engineering or Apply to Original. The new verification receipt is append-only; its target and historical result remain unchanged.
Street background and recovery
Choose Street map · OpenStreetMap or Enable streets… to approve native OpenStreetMap requests. The prompt explains that visible viewport coordinates are sent to the provider. Consent is remembered for this project/account/provider, not globally, and View → Revoke street-map permission removes it and switches to offline. No request is made without that permission; the feature does not bulk-download tiles. Provider errors retain electrical overlays and show Retry streets. Retry reopens the same provider explicitly; offline artwork is not represented as a real street map. OSM attribution remains visible when streets are on.
Physical harbour example and provenance
Project → Create populated harbour study example… now creates a separate v9 project. It never replaces the open owner network or rewrites v7/v8 receipts. This fictional 78 MW, 50 Hz demonstration has seven physical sites, eight buses and a co-located 132/33 kV primary transformer. Its cable route lengths and explicit sequence types determine R/X/B and declared MVA limits; the RMS declarations are regenerated from those exact values. A shared corridor is not a junction unless the electrical endpoints say so. Native positive-sequence equivalents are admitted only for balanced AC/RMS, not unbalanced fault or cable thermal qualification.
The real OpenStreetMap background supplies context only. Sites and cable corridors are authored fictional assumptions, not Rotterdam utility assets, surveyed installations, rights-of-way or manufacturer data. Geodesic length/type conversion checks establish internal consistency, not whether a cable may be built through a real parcel, road or waterway. Declared 500 A (132 kV) and 600 A (33 kV) limits are synthetic assumptions; the catalogue's placeholder ampacity is not used as evidence.
Map-first overview and station detail
The overview shows physical site names, plus abnormal voltages or internal-transformer loading. A multi-voltage site does not pick an arbitrary bus: its warning identifies the worst bus/voltage level; additional findings remain in Checks. Healthy raw values are available on selection. Nominal-voltage route colours are distinct from limit warnings; dashed OPEN connections remain explicit. Vm/Va colouring is optional and its scale/units stay in the legend. Study connections are conceptual, not surveyed routes.
Click a site to open Station: a native read-only local single-line, local busbars and internal transformers, plus boundary feeder stubs named for remote sites. Remote buses are not duplicated inside this station. Numerical bus voltages/angles and terminal MW/MVAr/loading track the exact shared recording/case/time. Recorded keeps equipment comparison and events; Source keeps immutable declarations and provenance. Large stations exceeding the bounded drawing profile remain available through source/virtual result tables, without pretending a partial drawing is complete.
Above 1000 logical pixels a single right drawer is used. Below that, station detail replaces the map. ← Map or Escape returns to the previous camera, selection and time; selecting the same site again reopens it. Panning the detail never edits equipment or geographic positions. Fit station only changes its local camera.
Local station demand/generation is shown separately from boundary feeders. In the v9 primary station, the local 18 MW load explains why the incoming transformer power is larger than the four remote feeder totals. Its readout uses exact retained Pl/Ql or P_g/Q_g channels and the retained MVA base. Demand is positive consumption (-Pl/-Ql); generation is positive injection. In a short inspector, scroll or Page Down to the numerical rows; the Map/fit controls stay reachable; missing channels say unavailable, never zero.
Compact controls and recovery
The context control opens Map source and recorded case, retaining full study/run/case names and exact underlying identities. Choosing a context does not edit Original or start a solver. Find / Ctrl+F opens source assets; Layers exposes optional overlays. Assets, the result Table, minimap Overview, legend, linked schematic and background choices are explicit actions, not permanently open panes. Table/time-series export, comparison, study library and Simulation remain available under View. Source details retain full identities even when a control is compact.
Checks → Verify results records geography separately from algebraic consistency, source constraints, data integrity and the independent initial AC reference. It checks site/voltage-level association, co-located transformer windings, route endpoints/lengths, source-bound type/base conversions and current-derived MVA limits. Missing declarations are unavailable; inconsistent data produce findings rather than silent coordinate/parameter repair. Old schema-1 audits remain readable but do not establish physical-map consistency. Synthetic provenance is never an attestation or engineering approval.
OSM consent, revoke/retry, offline overlays and visible attribution are unchanged. Background choices live under View → Background. The ready-state footer contains north/zoom and attribution; loading/provider failure still exposes diagnostics/retry without replacing the electrical model. OSM Standard uses only supported levels 0–19. Working/imported sources are never rebuilt automatically; explicit coordinate editing is separate from this read-only workspace.
Redundant industrial example and switch coverage
The latest fictional harbour example has two explicitly assumed 100 MVA 132/33 kV transformers, 78 MW of declared demand, two LV sections and a normally open coupler. Use the native scenario browser/Study Manager to choose Normal split buses, either transformer outage before transfer, or its manually restored configuration. Either transformer can supply the full demand after break-before-make transfer. The interruption is real in the model; no automatic protection, relay timing or uninterrupted-supply guarantee is claimed. Old examples and receipts remain unchanged.
Closed ideal switches use an explicit pinned-native bus-reduction map and source-terminal KCL current reconstruction. Native placeholder zero switch flows are not measurements. Switch current/rating are kA; continuous line/transformer rating is MVA. Ideal loops, unlike voltage levels and conflicting fused controls are rejected rather than assigned arbitrary currents. Disconnected unloaded bay voltages are unavailable/de-energized, never fabricated zero pu. Fixed-configuration RMS has a checked source/equivalent mapping and retains source bus/switch channels; ideal-switch topology changes during one recording are unsupported. Other study families must advertise their actual source/profile coverage, not silently drop switches.
Station includes real admitted switchgear, the authored source sheet and exact values. Click a symbol to inspect that equipment. Open sheet gives a larger read-only native view (wheel zoom, drag pan). Selecting a cable disables an unrelated Station tab rather than retaining misleading prior context. Detached candidate declarations are explicitly labelled, cannot edit Original and contain no solved values.
Real infrastructure reference
View → Real infrastructure reference is a separate, initially hidden read-only layer. It queries public OpenStreetMap power substations/lines/cables through a fixed Overpass endpoint for the bounded study area, after its own human confirmation. Street-tile permission does not grant reference-query permission. The provider receives your network address and area coordinates. View permits refresh, source inspection and revocation. Requests are asynchronous and capped by area, feature count, bytes and geometry points; a revoked or stale in-flight request cannot publish into a different source.
Purple dash-dot reference shapes are not study assets. Inspect real infrastructure sources shows original OSM IDs/tags, retrieval date, ODbL-1.0 attribution and incomplete-data limitations. Multi-part geometry remains separate, never an invented connection. Reference data cannot establish internal connectivity, operating switch states, currents, loads, R/X/B or manufacturer ratings, and is never automatically imported into a circuit. Cached source-integrity-checked data remain readable offline after network permission is revoked. Provider failures leave the electrical project unchanged; retry explicitly or use cached data. No AI tool can grant this network consent or engineering approval.
Network clarity, route groups and overview
The map toolbar offers Voltage classes and Feeder / route groups. Group colours come from each native branch's declared BranchGroup; unassigned branches remain explicit. These colours do not calculate feeder supply, loading or engineering acceptance. Open/out-of-service connections remain dashed and grey. G / load symbols identify actual attached native equipment, not invented results.
Use Network overview for the live whole-network inset. Click it to move the camera; focus it and use arrow keys to pan or Home to centre. The distance scale follows geographic zoom/latitude; it is not an installed electrical length. Map focus hides Properties and the equipment schedule to give the map space; toggle it again to restore the preceding panels. It does not discard inspector edits or modify the circuit.
In Map assets → Route groups, select which declared native groups are visible. Toggles are source-bound, view-only changes, not switching operations. Show all routes clears the filter. Display settings are remembered separately for the project/source; opening another source cannot borrow its group identities. Use the equipment schedule and station schematic for internal connections at the same geographic site.
Free historical satellite background
Map background → Satellite · Sentinel-2 2016/17 (free) uses only EOX's free 2016-vintage mosaic, containing modified Copernicus Sentinel data from 2016 and 2017. It is older satellite context, not live, high-resolution aerial photography or a surveyed network. Later changes/buildings may not appear. The application limits native tile zoom and does not invent detail when magnified.
EOX's provider FAQ and licence permit this vintage under CC BY 4.0, including reasonable commercial application access. Newer commercial-restricted layers are not selected. Attribution remains visible in the map and cached review previews:
> EOxCloudless https://cloudless.eox.at by EOX IT Services GmbH (Contains modified Copernicus Sentinel data 2016 & 2017) · CC BY 4.0
Choosing this provider requires its own account/project consent; existing OpenStreetMap consent does not grant it. Requests disclose the network address and visible tile extent to EOX, not the project file or electrical values. Only normal visible tiles are fetched sequentially and cached locally; there is no bulk-download/raw-tile export feature. The public endpoint has fair-use limits and no availability guarantee. On failure, electrical overlays and explicit error/retry state remain; switch to Streets or the offline coordinate grid. Revoke online background permissions stops the current provider and clears remembered background permissions. Cached before/proposed review images use only already-viewed tiles and preserve the correct provider attribution.
For a populated software-review example, open Fictional distribution district · six feeder groups. It contains 122 buses, 91 sites, 93 line routes, 31 transformers, 90 loads and six explicitly declared groups, including three normally open ties. All values and coordinates are fictional assumptions, not manufacturer/survey evidence. The example is separate from existing projects and contains no invented study results; run an admitted exact-input study to obtain actual results.