Specialist engineering workflows

Open these documents from Specialist engineering in the project tree or the Workspace menu. Opening, inspecting and refreshing never starts inference or a calculation. Use Build on a detached draft, supply the source/assumption and units, explicitly Save, then Run saved workflow. Incomplete definitions remain missing, not engineering facts. Retained results bind the exact saved definition, scenario and native artifact; later edits make them historical. Save pauses only the affected conversation through the existing takeover flow. Original is unchanged.

| Document | Supported analysis / explicit boundary | |---|---| | Arc-flash review | Review supplied energy, distance, fault/current and clearing-time evidence. No IEEE1584 calculation, PPE recommendation or approval. | | Motor starting | Fixed-PQ native AC snapshots at declared starting kVA, lagging PF and sequence fractions. No torque, speed or dynamic acceleration prediction. | | Harmonics | Explicit harmonic current injections through native passive positive-sequence admittance. Constant R, X/B scaled by frequency; ideal reference bus required. No converter/sequence response or compliance THD. | | Frequency sweep | Driving-point magnitude/phase in ohms/degrees at explicit frequencies/buses. Singular points are unavailable, never joined into a false curve. No source impedance is inferred. | | Identification | Fit a bounded first-order step response to source-aligned samples; chronological held-out samples never train. Rank, residuals and approximate local uncertainty retained. Not native RMS identification. | | Reliability | Expected independent event rates, affected customers and declared partial/full restoration yield SAIFI, SAIDI, CAIDI and ASAI with units. No switching commands or utility qualification. | | Reduction | Kron port reduction of native passive Ybus, with deterministic port-current checks. Generator/load/dynamic equivalence and automatic replacement are excluded. | | Phase allocation | Source-declared phases and allowed moves for actual native loads; review or a deterministic greedy proposal. No unbalanced voltage calculation or physical switching. | | Model distribution | Explicit include/exclude-source manifest for selected native models. Not encryption or enforced protection. Original native files and ordinary evidence packages can still contain source. | | Surrogates | Degree1–3 polynomial approximation, normalized training, held-out residuals and explicit domain. Out-of-domain requested predictions remain unavailable. Never replaces deterministic solver proof. | | Converter models | Inspect actual native converter/HVDC/UPFC/generator parameters and supported editor path. A declaration is not control/model/manufacturer qualification. | | Cable installation | Validate supplied cross-section overlap and multiply explicitly sourced derating factors by a sourced reference rating. Not an IEC thermal solution; ambient/soil/depth effects are not invented. | | Team access | Save and evaluate an offline declared access matrix and conflicts. No accounts, credentials, database ACLs or product permissions are changed. |

Editing and evidence

Tables support manual rows, editing and paste; enumerations/booleans use explicit choices. Invalid pasted values remain visible for correction. Save and Run are separate. Select a saved definition/retained result deliberately; following a job never resubmits it. Pending recovery and conflict merge retain both sides; no AI or calculation is replayed automatically. Native equipment inspection uses stable IDs, not table position, and preserves the exact detached editor/Original boundary.

Charts and compact result tables show actual quantities first. Expand exact retained evidence for IDs, sources, model applicability, parameters, residuals, failed/unavailable points and exported JSON/CSV. The standard receipt/evidence pipeline remains authoritative. Cancel requests settle through the job supervisor; no partially completed study is published as passing. A review-required result is not engineering approval. No live server/deployment or field operation is admitted.