Balanced RMS dynamics

Kind

rms

Interpretation

New setups use native-balanced-rms/2: select a 2.5 or 5 ms step and a duration of 0.5–100 s in exact 0.5 s increments, within 20,001 samples (maximum 50 s at 2.5 ms), 512 channels, 16 event groups and 200 MiB of retained arrays. Declared variable/group sizes are checked before allocation; the unchanged isolated-worker time budget can still stop an expensive run. Existing native-balanced-rms/1 requests and receipts retain exactly 5 s / 5 ms; restoring an old case never upgrades its profile. To change timing, explicitly select /2 and save a new case version. Every event must be on the selected step, at least one step after initialization and strictly before the requested end; shorten the horizon only after reviewing its events. The worker verifies the complete recorded grid against the exact request and does not interpolate or extend it. Raw native nanosecond timestamps remain unchanged; their pinned float-to-integer conversion can differ from the ideal grid by at most 1 ns, which is checked explicitly. It admits only explicitly declared native dynamic templates, exact candidate-bound parameter/source declarations, active event groups and a small set of step-aligned events. It does not accept scenario overrides, infer model constants or qualify every VeraGrid RMS template. The packaged synthetic port example demonstrates baseline, finite synthetic shunt apply/clear and a synthetic line trip. The adapter records the requested event time, its one-sample-earlier native schedule and checks the measured transition at the requested sample for this tested profile. Inspect every group's initialization, convergence, availability and transition check. The immutable receipt holds timestamps, channel IDs/units, arrays and hashes. The Qt result view plots only available groups; unknown units and failed data remain unavailable. Schedule markers are not physical-onset measurements. A run is review-required, not engineering approval or plant/protection qualification. See RMS studies for exact limits, workflow, plot/export, AI access and failure recovery.

Run

Discover settings with study definitions. Select an exact network snapshot and case version; inspect readiness. Submit once using study_submit or the case submission tool, monitor study_status, then inspect study_results. Keep input/configuration/solver identities, warnings and failure states.

Compare and accept

Use equivalent settings/units and exact receipts. Unsupported or incompatible inputs remain explicit. Numerical qualification and human acceptance are separate. See Studies.