AC state estimation

Kind

state-estimation

Interpretation

Runs the pinned VeraGrid weighted least-squares AC estimator against a frozen native candidate and an explicit measurement set. Supported records are bus voltage magnitude (pu), bus net active/reactive injection (MW/MVAr), and branch terminal P/Q flow (MW/MVAr). Each measurement binds a stable ID, exact native device ID, value, positive sigma, unit, source and source/synthetic basis. The worker does not save measurements into the project or alter imported data. It reports convergence, observability, estimated bus states and signed/standardized residuals. Native bad-data detection is not used: residuals are for human review, not an automated outlier verdict, correction or removal. Pseudo-measurements are disabled. Bind the same measurement set to exact source data and a scenario before comparing receipts. Unobservable, non-converged, inactive-device, invalid-unit, unknown-ID and missing-source cases fail visibly. This is balanced static AC estimation only; it does not connect SCADA, validate sensor calibration or approve operation. See state-estimation studies.

Measurement setup and recovery

In Studies select AC state estimation, refresh the exact candidate, then choose Edit measurement set. Pick a bus or branch by its displayed label while retaining its exact native ID. Add one row per actual observation: unique measurement_id; device_id; quantity; finite measured value; positive standard deviation sigma; exact unit; basis (source-data or synthetic-assumption); and a concise source. Bus quantities are vm (pu), pi (MW) and qi (MVAr); branch terminal quantities are pf/pt (MW) and qf/qt (MVAr). The UI derives units from the chosen quantity. Do not mix units, refer to inactive equipment, guess missing observations, or reuse the set after the selected scenario/model changes without reopening and confirming it. Run once; inspect initialization/convergence/observability before estimates, then review each signed residual and residual/sigma beside the source. Unobservable islands or non-convergence fail the run. No native bad-data flag, automatic correction/removal or pseudo-measurement is accepted. The immutable receipt binds the artifact, full measurements and solver/runtime identity. study_results exposes paged, unit-tagged estimates and residuals; same-receipt project tables are not new measurements. Plan may inspect existing evidence only; Build submits the exact set as a detached study, never edits Main/Original. A successful status is not sensor-quality validation or operational approval.

Run

Discover settings with study definitions. Select an exact network snapshot and case version; inspect readiness. Submit once using study_submit or the case submission tool, monitor study_status, then inspect study_results. Keep input/configuration/solver identities, warnings and failure states.

Compare and accept

Use equivalent settings/units and exact receipts. Unsupported or incompatible inputs remain explicit. Numerical qualification and human acceptance are separate. See Studies.