Guide contents

Underground Line Type

Native property registrations from the pinned engine; not certification of this equipment. Use native IDs and inspect actual object state. Absence is not zero. Definitions/units/types below are exact source declarations, not guessed conversions. See Projects.

Imax

Current rating of the line

Unit: kA Type: float Profile: none declared

Vnom

Voltage rating of the line

Unit: kV Type: float Profile: none declared

freq

Cable frequency

Unit: Hz Type: float Profile: none declared

earth_resistivity

Earth resistivity

Unit: Ohm*m Type: float Profile: none declared

cables_in_system

Physical cables and their positions

Unit: not declared Type: SubObjectType.ListOfCables Profile: none declared

R

Positive-sequence resistance per km

Unit: Ohm/km Type: float Profile: none declared

X

Positive-sequence reactance per km

Unit: Ohm/km Type: float Profile: none declared

B

Positive-sequence shunt susceptance per km

Unit: uS/km Type: float Profile: none declared

C

Positive-sequence shunt capacitance per km (alternative to B

Unit: uF/km Type: float Profile: none declared

R0

Zero-sequence resistance per km

Unit: Ohm/km Type: float Profile: none declared

X0

Zero-sequence reactance per km

Unit: Ohm/km Type: float Profile: none declared

B0

Zero-sequence shunt susceptance per km

Unit: uS/km Type: float Profile: none declared

C0

Zero-sequence shunt capacitance per km (alternative to B0

Unit: uF/km Type: float Profile: none declared

n_circuits

number of circuits

Unit: not declared Type: int Profile: none declared

capex

Capital expenditure per km

Unit: currency/km Type: float Profile: none declared

opex

Operational expenditure

Unit: currency/MWh Type: float Profile: none declared