Commitment schedule
Kind
commitment
Interpretation
Explicit native forecasts, costs, initial state and on/off/ramp constraints; native HiGHS then independent schedule and AC checks. See Advanced engineering.
Inputs, units and recovery
Declare 2–96 profile instants, 1–32 generators and intervals of 1/60–24 hours. Supply initial MW, on/off state, ramps, minimum up/down times and explicit currency costs. Bind the exact saved definition, candidate artifact and scenario. Opening the view never runs this calculation. Review missing inputs, exclusions and worker failures before submitting once. Repair the declared source or settings explicitly, save a new version and retain earlier receipts as historical. Reopening a result never retries inference, fills missing engineering facts or grants approval.
Run
Discover settings with study definitions. Select an exact network snapshot and case version; inspect readiness. Submit once using study_submit or the case submission tool, monitor study_status, then inspect study_results. Keep input/configuration/solver identities, warnings and failure states.
Compare and accept
Use equivalent settings/units and exact receipts. Unsupported or incompatible inputs remain explicit. Numerical qualification and human acceptance are separate. See Studies.