Controllable Branch Parent

Propriétés déclarées du moteur épinglé, pas une certification. Utilisez les identifiants natifs. Les définitions/unités/types sont conservés dans leur langue source sans conversion supposée. Absent n’est pas zéro. Voir Projets.

R

Total positive sequence resistance.

Unit: p.u. Type: float Profile: none declared

X

Total positive sequence reactance.

Unit: p.u. Type: float Profile: none declared

G

Total positive sequence shunt conductance.

Unit: p.u. Type: float Profile: none declared

B

Total positive sequence shunt susceptance.

Unit: p.u. Type: float Profile: none declared

R0

Total zero sequence resistance.

Unit: p.u. Type: float Profile: none declared

X0

Total zero sequence reactance.

Unit: p.u. Type: float Profile: none declared

G0

Total zero sequence shunt conductance.

Unit: p.u. Type: float Profile: none declared

B0

Total zero sequence shunt susceptance.

Unit: p.u. Type: float Profile: none declared

R2

Total negative sequence resistance.

Unit: p.u. Type: float Profile: none declared

X2

Total negative sequence reactance.

Unit: p.u. Type: float Profile: none declared

G2

Total negative sequence shunt conductance.

Unit: p.u. Type: float Profile: none declared

B2

Total negative sequence shunt susceptance.

Unit: p.u. Type: float Profile: none declared

tolerance

Tolerance expected for the impedance values% is expected for transformers0% for lines.

Unit: % Type: float Profile: none declared

tap_changer

Tap changer object

Unit: not declared Type: SubObjectType.TapChanger Profile: none declared

tap_module

Tap changer module, it a value close to 1.0

Unit: not declared Type: float Profile: tap_module_prof

tap_module_max

Tap changer module max value

Unit: not declared Type: float Profile: none declared

tap_module_min

Tap changer module min value

Unit: not declared Type: float Profile: none declared

tap_module_control_mode

Control available with the tap module

Unit: not declared Type: TapModuleControl Profile: tap_module_control_mode_prof

vset

Objective voltage at the "to" side of the bus when regulating the tap.

Unit: p.u. Type: float Profile: vset_prof

Qset

Objective power at the selected side.

Unit: MVAr Type: float Profile: Qset_prof

regulation_bus

Bus where the regulation is applied.

Unit: not declared Type: DeviceType.BusDevice Profile: none declared

tap_phase

Angle shift of the tap changer.

Unit: rad Type: float Profile: tap_phase_prof

tap_phase_max

Max angle.

Unit: rad Type: float Profile: none declared

tap_phase_min

Min angle.

Unit: rad Type: float Profile: none declared

tap_phase_control_mode

Control available with the tap angle

Unit: not declared Type: TapPhaseControl Profile: tap_phase_control_mode_prof

Pset

Objective power at the selected side.

Unit: MW Type: float Profile: Pset_prof