Sommaire du manuel

Vsc

Propriétés déclarées du moteur épinglé, pas une certification. Utilisez les identifiants natifs. Les définitions/unités/types sont conservés dans leur langue source sans conversion supposée. Absent n’est pas zéro. Voir Projets.

bus_dc_n

DC negative bus

Unit: not declared Type: DeviceType.BusDevice Profile: none declared

alpha1

Losses constant parameter (IEC 62751-2 loss Correction, idle loss).

Unit: not declared Type: float Profile: none declared

alpha2

Losses linear parameter (IEC 62751-2 loss Correction, Switching loss).

Unit: not declared Type: float Profile: none declared

alpha3

Losses quadratic parameter (IEC 62751-2 loss Correction, resistive loss).

Unit: not declared Type: float Profile: none declared

r_series

Converter series-reactor resistance on the converter base.

Unit: p.u. Type: float Profile: none declared

x_series

Converter series-reactor reactance on the converter base.

Unit: p.u. Type: float Profile: none declared

dc_voltage_base

Native converter DC voltage base used by dynamic models.

Unit: kV Type: float Profile: none declared

Equivalent capacitance directly across the DC terminals.

Unit: uF Type: float Profile: none declared

mmc_arm_capacitance_uf

Equivalent capacitance of one MMC arm.

Unit: uF Type: float Profile: none declared

mmc_consider_arm_reactor_dc

Whether the MMC arm reactor is represented on the DC side.

Unit: not declared Type: bool Profile: none declared

phN

Is the neutral connected?

Unit: not declared Type: bool Profile: none declared

phA

Is phase A connected?

Unit: not declared Type: bool Profile: none declared

phB

Is phase B connected?

Unit: not declared Type: bool Profile: none declared

phC

Is phase C connected?

Unit: not declared Type: bool Profile: none declared

control1

Control mode 1.

Unit: not declared Type: ConverterControlType Profile: control1_prof

control1_dev

Controlled device, None to apply to this converter

Unit: not declared Type: DeviceType.BusOrBranch Profile: control1_dev_prof

control1_val

Control value 1.p.u. for voltage rad for angles MW for P MVAr for Q

Unit: not declared Type: float Profile: control1_val_prof

control1_val_min

Native registered property; consult the selected object and admitted study profile before editing.

Unit: not declared Type: float Profile: none declared

control1_val_max

Native registered property; consult the selected object and admitted study profile before editing.

Unit: not declared Type: float Profile: none declared

control1_val_droop

Native registered property; consult the selected object and admitted study profile before editing.

Unit: not declared Type: float Profile: control1_val_droop_prof

control1_droop_val

Native registered property; consult the selected object and admitted study profile before editing.

Unit: not declared Type: float Profile: control1_droop_val_prof

control1_droop_val_min

Native registered property; consult the selected object and admitted study profile before editing.

Unit: not declared Type: float Profile: none declared

control1_droop_val_max

Native registered property; consult the selected object and admitted study profile before editing.

Unit: not declared Type: float Profile: none declared

control2

Control mode 2.

Unit: not declared Type: ConverterControlType Profile: control2_prof

control2_dev

Controlled device, None to apply to this converter

Unit: not declared Type: DeviceType.BusOrBranch Profile: control2_dev_prof

control2_val

Control value 2.p.u. for voltage rad for angles MW for P MVAr for Q

Unit: not declared Type: float Profile: control2_val_prof

control2_val_min

Native registered property; consult the selected object and admitted study profile before editing.

Unit: not declared Type: float Profile: none declared

control2_val_max

Native registered property; consult the selected object and admitted study profile before editing.

Unit: not declared Type: float Profile: none declared

control2_val_droop

Native registered property; consult the selected object and admitted study profile before editing.

Unit: not declared Type: float Profile: control2_val_droop_prof

control2_droop_val

Native registered property; consult the selected object and admitted study profile before editing.

Unit: not declared Type: float Profile: control2_droop_val_prof

control2_droop_val_min

Native registered property; consult the selected object and admitted study profile before editing.

Unit: not declared Type: float Profile: none declared

control2_droop_val_max

Native registered property; consult the selected object and admitted study profile before editing.

Unit: not declared Type: float Profile: none declared

fault_control

VSC control system during a short-circuit event.

Unit: not declared Type: ConverterFaultControlType Profile: fault_control_prof

min_ac_voltage

Minimum AC voltage threshold. If the AC bus voltage drops below this value, the VSC is disconnected.

Unit: p.u. Type: float Profile: none declared

ysvs

Admittance of non-controlled Static Var Systems.

Unit: p.u. Type: float Profile: none declared

x

x position

Unit: px Type: float Profile: none declared

y

y position

Unit: px Type: float Profile: none declared