Sommaire du manuel

Branch

Propriétés déclarées du moteur épinglé, pas une certification. Utilisez les identifiants natifs. Les définitions/unités/types sont conservés dans leur langue source sans conversion supposée. Absent n’est pas zéro. Voir Projets.

R

Total positive sequence resistance.

Unit: p.u. Type: float Profile: none declared

X

Total positive sequence reactance.

Unit: p.u. Type: float Profile: none declared

B

Total positive sequence shunt susceptance.

Unit: p.u. Type: float Profile: none declared

G

Total positive sequence shunt conductance.

Unit: p.u. Type: float Profile: none declared

tolerance

Tolerance expected for the impedance values % is expected for transformers0% for lines.

Unit: % Type: float Profile: none declared

length

Length of the line (not used for calculation)

Unit: km Type: float Profile: none declared

tap_module

Tap changer module, it a value close to 1.0

Unit: not declared Type: float Profile: none declared

angle

Angle shift of the tap changer.

Unit: rad Type: float Profile: none declared

bus_to_regulated

Is the regulation at the bus to?

Unit: not declared Type: bool Profile: none declared

vset

set control voltage.

Unit: p.u. Type: float Profile: none declared

r_fault

Fault resistance.

Unit: p.u. Type: float Profile: none declared

x_fault

Fault reactance.

Unit: p.u. Type: float Profile: none declared

fault_pos

proportion of the fault location measured from the "from" bus.

Unit: p.u. Type: float Profile: none declared